Independent Wall Solution
This is the best solution for eliminating airborne and vibration noise. Total space loss 11cm.
- build a frame from the floor to the ceiling adjacent to the existing wall using 2×2 batons, with a minimum gap of 1.5cm between the 2 walls
- insert 50mm high density acoustic mineral wool (RS60) between the batons
- fix resilient bars to the frame
- attach 19mm sound plank plasterboard to the resilient bars
- seal all joints with acoustic mastic
- attach final layer of 12.5mm of sound shield plasterboard
- plaster finish to the soundproofed area
26 db noise reduction
Resilient Bars Solution
This is a very effective solution with less space loss. Total space loss 9cm.
- attach new joists to the existing wall using 2×2 batons,
- insert high density acoustic mineral wool (RS60) between the batons
- fix resilient bars to the frame
- attach 19mm sound plank plasterboard to the resilient bars
- seal all joints with acoustic mastic
- attach final layer of 12.5mm of sound shield plasterboard
- plaster finish to the soundproofed area
20 db noise reduction
M20 Panels Solution
This solution can be used when space is at a premium as it involves the minimum space loss. Total space loss 5cm.
- attach M20 panels to the existing wall using special strong grip adhesive
- seal all joints with acoustic mastic
- attach 15mm sound shield plasterboard.
- seal all joints with acoustic mastic
- attach final layer of 15mm sound shield plasterboard.
- plaster finish to the soundproofed area
19 db noise reduction.
It is recommended with the above solution to replace one layer of Soundshield plasterboard with a layer of 15mm dB board acoustic panel .
There are a number of optional upgrades that can be added to the
above solutions, depending on the noise transference and the layout of the property. Please get in touch for more details