Independent Wall Solution

This is the best solution for eliminating airborne and vibration noise. Total space loss 11cm.

  • build a frame from the floor to the ceiling adjacent to the existing wall using 2×2 batons, with a minimum gap of 1.5cm between the 2 walls
  • insert 50mm high density acoustic mineral wool (RS60) between the batons
  • fix resilient bars to the frame
  • attach 19mm sound plank plasterboard to the resilient bars
  • seal all joints with acoustic mastic
  • attach final layer of 12.5mm of sound shield plasterboard
  • plaster finish to the soundproofed area

26 db noise reduction

Resilient Bars Solution

This is a very effective solution with less space loss. Total space loss 9cm.

  • attach new joists to the existing wall using 2×2 batons,
  • insert high density acoustic mineral wool (RS60) between the batons
  • fix resilient bars to the frame
  • attach 19mm sound plank plasterboard to the resilient bars
  • seal all joints with acoustic mastic
  • attach final layer of 12.5mm of sound shield plasterboard
  • plaster finish to the soundproofed area

20 db noise reduction

M20 Panels Solution

This solution can be used when space is at a premium as it involves the minimum space loss. Total space loss 5cm.

  • attach M20 panels to the existing wall using special strong grip adhesive
  • seal all joints with acoustic mastic
  • attach 15mm sound shield plasterboard.
  • seal all joints with acoustic mastic
  • attach final layer of 15mm sound shield plasterboard.
  • plaster finish to the soundproofed area

19 db noise reduction.

It is recommended with the above solution to replace one layer of Soundshield plasterboard with a layer of 15mm dB board acoustic panel .

There are a number of optional upgrades that can be added to the
above solutions, depending on the noise transference and the layout of the property. Please get in touch for more details

For more information please just get in touch.